63 Litre Top Loading Compact Autoclave Range

The 63 litre 'Compact' top loading autoclaves are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single phase power supply. All compact autoclaves are fitted with castors for easy movement.

Available in two versions; they are idea for a medical application, for sterilizing tall items, or in any situation where space is at a premium. ‘Classic’ and ‘Ecofill’ models are available.



View Products in Stock

Description

Ecofill 'Compact' top loading autoclave:

The ‘Ecofill’ version has an integral reservoir and an in-built 'autofill' water re-circulation system. Once the reservoir is filled, this provides water for up to 15 cycles, and also acts as a collection vessel for condensate and the water that is automatically returned from the chamber at the end of each cycle, minimising water usage.

Classic 'Compact' top loading autoclave:

The ‘Classic’ version requires manual water-fill and during the cycle condensate leaves the vessel via a silicone tube that can be connected to a heat-resistant bottle.

Astell can custom build the Compact range to your specifications.

Model: AMA240 Autofill (63 litres)
Model: AMA440 Classic (63 litres)
Features
  • 316 stainless steel electropolished chamber
  • Base shelf within the chamber
  • Calibration and Validation available
  • Castor mounted for easily moving the unit
  • FDA 21 CFR part 11 software option available
  • Cooling Lock
  • Fast action door closure mechanism
  • Five password levels to stop lower level users making changes
  • Five pre-programmed cycles and up to 50 available
  • Holdwarm / Delayed Start feature
  • No mains water supply or drain necessary
  • Optimised for low water and power consumption
  • Over Temperature Protection
  • Pressure Gauge
  • Self contained design with no installation required - just fill it with water and plug it in and the machine is ready to be used
  • Standard Astell safety features
  • Temperature range of 100°C to 138°C (0.2 - 2.4 Bar)
  • Timed/Pulsed Free Steaming
  • Fully programmable 5.7" Colour Touch Screen controller
  • USB interface for downloading controller data
  • Validation Port

Product Options

  • 21 CFR 11 controller software 21 CFR 11 controller software
  • Assisted Air Cooling (only available for non-vacuum models) Assisted Air Cooling (only available for non-vacuum models)
  • CAT III (BSL3) compliance (>63L) CAT III (BSL3) compliance (>63L)
  • Condensate Bottle (for 'Classic' models only) Condensate Bottle (for 'Classic' models only)
  • Ethernet interface Ethernet interface
  • Integral Data Printer Integral Data Printer
  • IQ/OQ documentation IQ/OQ documentation
  • Load Sensed Process Timing Load Sensed Process Timing
  • Load Support Plate Load Support Plate
  • Morrison Discard Container (310 x 270mm) Morrison Discard Container (310 x 270mm)
  • Pulsar Freesteaming (only available on non-vacuum models) Pulsar Freesteaming (only available on non-vacuum models)
  • Remote maintenance/diagnosis Remote maintenance/diagnosis
  • Stainless Steel basket (310x270mm) Stainless Steel basket (310x270mm)

Related Case Study

Vets Now: Case Study

Compact autoclave with vacuum facilities rapidly cools the chamber leaving surgical instruments touch dry for Vets Now.

Read

Autoclave calibration and validation are vital to many laboratory activities. In this CRT article we explain the difference between them.

19 September 2019
Read

Two new 490 litre Double Door SQUARE range units Validated and installed in Scotland.

14 August 2019
Read

Paul Birchmore explains the best way to manage effluent decontamination in contained laboratories whilst avoiding the use of toxic chemicals.

09 August 2019
Read