AMB Ecofill Benchtop Autoclave (33 to 63 Litres)
AMB Ecofill Benchtop Autoclave - Front View
Model: AMB230 Ecofill Benchtop Autoclave (43 litres)
Model: AMB240 Ecofill Benchtop Autoclave (63 litres)
AMB Ecofill Benchtop Autoclave (33 to 63 Litres)
The Astell AMB Ecofill Benchtop Autoclaves provide ultra energy, water, and time saving results when compared to similar benchtop sterilizers. Sacrificing the optional CAT III filter upgrade that gives AMB Classic Benchtop Biosafety Level 3 / Containment Level 3 compatibility allows the AMB Ecofill Benchtops to instead include the Ecofill System. This system adds to the already numerous energy saving features found in both the Classic and Ecofill AMB Benchtop Autoclaves, including using only heating one litre generate steam, alongside power saving software developments built into the touchscreen control computer.
Astell’s Ecofill system adds a water reservoir to the autoclave. This reservoir is simply filled via a port on the top of unit, rather than filling the bottom of the autoclave chamber with water. Water is automatically supplied to the autoclave chamber on demand, then returned to the reservoir when not required, capturing both water and heat energy. This process allows the Ecofill system to save water, processing time, and energy when compared to an autoclave without Ecofill when cycles are run back-to-back. Additionally, Ecofill autoclaves can run for 15 cycles before it requires refilling, providing greater simplicity and time efficiency.
Like their Classic equivalents, the AMB Ecofill Autoclaves are plug and play units. Unlike many of their larger counterparts, they do not require plumbing into a water supply or drain system. Furthermore they only require plugging into domestic electricity supply. This makes them simple to install in a laboratory or sterilization room setting – simply place them near enough to an electrical socket and plug them in.
AMB Ecofill Benchtop Autoclaves can sterilize a wide range of items and materials, including laboratory glassware, autoclavable plastics, instruments, liquids, growth media, discard, and biologically contaminated waste materials. The AMB Ecofill Benchtop Autoclaves cannot process Containment Level 3 / Biosafety Level 3 materials – for this functionality please see the AMB Classic Benchtop Autoclave. It can also not process wrapped instruments that require drying, for this ability please see the AMB Ecofill Dry Benchtop Autoclave. Those sterilizing beakers, conical flasks, test tubes, and other similar laboratory glassware and plasticware should consider the Nelldorn Glassware Dryer for a fast and efficient method of drying these items, making them ready for reuse.
These autoclaves are useful for a wide range of industries, and are found in laboratories across the research, food and drink, industrial and manufacturing, and medical and healthcare sectors.
Astell autoclaves are used in scientific research worldwide. View selected peer-reviewed research papers that reference their use in experimental methodology.
Contact us now on +44 (0)20 8309 2031 to find out more, or request a quotation by clicking here. For organisations outside the UK, please contact your national dealer who can be found on our Find a Dealer page.
Range Classification
This product has received Sustainability Awards from SLS. Click to find out more.
View Product Options View Products in Stock
Features
- 316 stainless steel electropolished chamber
- A choice of 33, 43 and 63 litre models
- Base shelf within the chamber
- Calibration and Validation available
- Cooling Lock
- Fast action door closure mechanism
- Five pre-programmed cycles and up to 50 available
- Float Switch Level Control (water)
- Holdwarm / Delayed Start feature
- No mains water supply or drain necessary
- Optimised for low water and power consumption
- Over Temperature Protection
- Pressure Gauge
- Self contained design with no installation required - just fill it with water and plug it in and the machine is ready to be used
- Standard Astell safety features
- Temperature range of 100°C to 138°C (0.2 - 2.4 Bar)
- Timed/Pulsed Free Steaming
- Fully programmable 5.7" Colour Touch Screen controller
- USB interface for downloading controller data
- Validation Port
Product Options
SLS Sustainable Features Awards
This autoclave has been recognized by Scientific Laboratory Supplies for its outstanding sustainable features through the following awards.
Sustainable Raw Material Award
Material resource efficiency principles have been embedded into the design.
Sustainable Product Manufacturing Award
Feature of manufacturing process designed to generate less waste.
Sustainable Distribution & Packaging Award
Manufacturing facility located in UK or Ireland. Country of origin has an Environmental Performance Index (EPI) greater than 60 (2022). Plastic free packaging. Product reduces need for packaging. Packaging return scheme offered.
Sustainable Use Award
Product feature reduces energy consumption. Product feature reduces water consumption. Built to last. Minimum 5+ year warranty with software support (if applicable) and spare parts and servicing available.
Sustainable Disposal Award
Product is recyclable (supplier must offer a recycling or repurposing scheme for lab products) – excludes packaging.
Icons courtesy of Scientific Laboratory Supplies
Specifications and Options for 33-63 Litre Ecofill Benchtop Autoclaves
AMB220 - 33 Litre Ecofill Benchtop Autoclave
The AMB220 is a Low Water and Power Consumption 33 Litre Ecofill Benchtop Autoclave with a circular front-facing chamber aperture and the Astell Ecofill water and heat recycling system. It is compatible with optional components for additional sterilization, documentation, cooling, connectivity, validation and compliance requirements.
| Model code | AMB220 |
|---|---|
| Product name | 33 Litre Ecofill Benchtop Autoclave |
| Range | Low Water and Power Consumption |
| Product type | Benchtop Ecofill Autoclave with a Circular Front Facing Chamber Aperture |
| Description | An Astell autoclave with a 33 litre chamber that has a circular front-facing aperture, with the Astell Ecofill water and heat recycling system. Compatible with a range of optional components to extend the range of sterilizable load types. |
AMB220 specifications
Air
| Specification | Value | Unit |
|---|---|---|
| Peak Air Flow For Air Ballast | N/A | Litres per minute |
| Connecting Airline Hose Size For Air Ballast | N/A | mm |
| Peak Air Pressure For Air Ballast | N/A | bar |
| Second Airline Supply Connection Size | N/A | mm |
| Second Peak Air Supply Flow | N/A | Litres per minute |
| Second Peak Air Supply Pressure | N/A | bar |
| Second Air Supply Use | N/A |
Chamber
| Specification | Value | Unit |
|---|---|---|
| Chamber Depth | 358 | mm |
| Chamber Finish | Electropolished | |
| Chamber Height | 345 | mm |
| Chamber Volume | 33 | Litres |
| Chamber Width | 345 | mm |
Drain
| Specification | Value | Unit |
|---|---|---|
| Required Features of Drainage System | N/A | |
| Drain Material | N/A | |
| Drain Position | N/A | |
| Drain Size | N/A | mm |
| Drainpipe Connection | N/A | |
| Maximum Drain Height | N/A | mm |
Dimensions
| Specification | Value | Unit |
|---|---|---|
| Dry Weight | 75 | kg |
| Product Height | 605 | mm |
| Product Width | 520 | mm |
| Product Depth | 808 | mm |
| Product Footprint | 0.25 | square metres |
Electrical
| Specification | Value | Unit |
|---|---|---|
| Max Frequency | TBC | Hz |
| Max Voltage | 230 | V |
| Max Wattage | TBC | kW |
| Standard Amperage | 13 | A |
| Power Of Steam Source | 2.3 | kW |
| Single Phase Availability | Available |
Water
| Specification | Value | Unit |
|---|---|---|
| Maximum Water Flow Rate | Infinity | Litres per minute |
| Minimum Water Flow Rate | 0 | Litres per minute |
| Water Enters Via | a water jug, filled from a tap |
Process
| Specification | Value | Unit |
|---|---|---|
| Steam Source | In-chamber water heating element |
| Option code | Option name | Description | Features |
|---|---|---|---|
| AAP007 | Chamber Vessel Cooling Fan System | Blows air across the external surfaces of the sterilization chamber vessel to improve cooling times. | Provides Cooling; Speeds Up Cycle Times |
| AAR014 | Load Sensed Process Timing | A temperature probe with an armoured lead is added to the chamber. Placed inside fluid loads, this probe provides accurate measurement of liquid temperatures, allowing for faster and more controlled liquid sterilization. | Fluid Handling Safety Feature; Improves Liquid Loads |
| AAR122 | Ethernet Interface | Allows the autoclave controller to be monitored from compatible digital systems. | Data / Connectivity Feature |
| AAR130 | Integral Data-Printer | Allows for the generation of physical records. | Generates Cycle Records and Printouts |
| AVC002S | Simple Vacuum | Provides a vacuum phase before and after sterilization to aid with air removal and load drying, reducing time to sterilization. Suitable for use with in-chamber steam generation. | Improves Air Removal; Requires Compressed Air; Speeds Up Cycle Times |
| CFR021 | FDA 21 CFR Part 11 Compliant Controller Software | Provides compliance to the requirements of 21 CFR Part 11 through data security, data integrity, traceability/audit trails, and electronic signature rules. | Compliance / Regulatory Feature; Data / Connectivity Feature |
| AAN022 | Additional Shelf For AAN025 Shelf Rack | An additional shelf on anti-tilt brackets, typically placed in the centre of the autoclave, providing approximately twice the usable width and depth of chamber space. | Modifies Chamber Loading Capabilities |
| AAN025 | 5 Position Shelf Rack With 2 Shelves | An additional shelf on anti-tilt brackets, typically placed in the centre of the autoclave, providing approximately twice the usable width and depth of chamber space. | Modifies Chamber Loading Capabilities |
| AAN346 | Discard Container | A cuboid container that allows the loading and unloading of multiple items simultaneously. | Simplifies Loading and Unloading Procedures |
| IQ/OQ001 | IQ/OQ Documents Package | Completion of the Installation Qualification (IQ) and Operational Qualification (OQ) documentation by an Astell Service Engineer. Requires verification to be valid. | Compliance / Regulatory Feature |
| IQ/OQ003 | Completion of IQ/OQ Documentation | Completion of the Installation Qualification (IQ) and Operational Qualification (OQ) documentation by an Astell Service Engineer. Requires verification to be valid. | Compliance / Regulatory Feature |
| UKAS001 | UKAS Calibration | Calibration of the autoclave to specified temperatures as per the requirements of ISO 17025:2005. | Compliance / Regulatory Feature |
| UKASVAL | Load Validation | Multipoint Load Validation Service provided by an Astell Services Autoclave Engineer. | Compliance / Regulatory Feature; Provides Validated Evidence of Load Meeting Requirements |
AMB230 - 43 Litre Ecofill Benchtop Autoclave
The AMB230 is a Low Water and Power Consumption 43 Litre Ecofill Benchtop Autoclave with a circular front-facing chamber aperture and the Astell Ecofill water and heat recycling system. It is compatible with optional components for additional sterilization, documentation, cooling, connectivity, validation and compliance requirements.
| Model code | AMB230 |
|---|---|
| Product name | 43 Litre Ecofill Benchtop Autoclave |
| Range | Low Water and Power Consumption |
| Product type | Benchtop Ecofill Autoclave with a Circular Front Facing Chamber Aperture |
| Description | An Astell autoclave with a 43 litre chamber that has a circular front-facing aperture, with the Astell Ecofill water and heat recycling system. Compatible with a range of optional components to extend the range of sterilizable load types. |
AMB230 specifications
Air
| Specification | Value | Unit |
|---|---|---|
| Peak Air Flow For Air Ballast | N/A | Litres per minute |
| Connecting Airline Hose Size For Air Ballast | N/A | mm |
| Peak Air Pressure For Air Ballast | N/A | bar |
| Second Airline Supply Connection Size | N/A | mm |
| Second Peak Air Supply Flow | N/A | Litres per minute |
| Second Peak Air Supply Pressure | N/A | bar |
| Second Air Supply Use | N/A |
Chamber
| Specification | Value | Unit |
|---|---|---|
| Chamber Depth | 465 | mm |
| Chamber Finish | Electropolished | |
| Chamber Height | 345 | mm |
| Chamber Volume | 43 | Litres |
| Chamber Width | 345 | mm |
Drain
| Specification | Value | Unit |
|---|---|---|
| Required Features of Drainage System | N/A | |
| Drain Material | N/A | |
| Drain Position | N/A | |
| Drain Size | N/A | mm |
| Drainpipe Connection | N/A | |
| Maximum Drain Height | N/A | mm |
Dimensions
| Specification | Value | Unit |
|---|---|---|
| Dry Weight | 95 | kg |
| Product Height | 605 | mm |
| Product Width | 520 | mm |
| Product Depth | 808 | mm |
| Product Footprint | 0.26 | square metres |
Electrical
| Specification | Value | Unit |
|---|---|---|
| Max Frequency | TBC | Hz |
| Max Voltage | 240 | V |
| Max Wattage | TBC | kW |
| Standard Amperage | 13 | A |
| Power Of Steam Source | 2.3 | kW |
| Single Phase Availability | Available |
Water
| Specification | Value | Unit |
|---|---|---|
| Maximum Water Flow Rate | Infinity | Litres per minute |
| Minimum Water Flow Rate | 0 | Litres per minute |
| Water Enters Via | a water jug, filled from a tap |
Doors
| Specification | Value | Unit |
|---|---|---|
| Number Of Doors | 1 |
Process
| Specification | Value | Unit |
|---|---|---|
| Steam Source | In-chamber water heating element | |
| Fitted Vacuum System | Optional |
| Option code | Option name | Description | Features |
|---|---|---|---|
| AVC002S | Simple Vacuum | Provides a vacuum phase before and after sterilization to aid with air removal and load drying, reducing time to sterilization. Suitable for use with in-chamber steam generation. | Improves Air Removal; Requires Compressed Air; Speeds Up Cycle Times |
| CFR021 | FDA 21 CFR Part 11 Compliant Controller Software | Provides compliance to the requirements of 21 CFR Part 11 through data security, data integrity, traceability/audit trails, and electronic signature rules. | Compliance / Regulatory Feature; Data / Connectivity Feature |
| AAP007 | Chamber Vessel Cooling Fan System | Blows air across the external surfaces of the sterilization chamber vessel to improve cooling times. | Provides Cooling; Speeds Up Cycle Times |
| AAR014 | Load Sensed Process Timing | A temperature probe with an armoured lead is added to the chamber. Placed inside fluid loads, this probe provides accurate measurement of liquid temperatures, allowing for faster and more controlled liquid sterilization. | Fluid Handling Safety Feature; Improves Liquid Loads |
| AAR122 | Ethernet Interface | Allows the autoclave controller to be monitored from compatible digital systems. | Data / Connectivity Feature |
| AAR130 | Integral Data-Printer | Allows for the generation of physical records. | Generates Cycle Records and Printouts |
| AAN346 | Discard Container | A cuboid container that allows the loading and unloading of multiple items simultaneously. | Simplifies Loading and Unloading Procedures |
| AAN530 | 5 Position Shelf Rack With 3 Shelves | An additional shelf on anti-tilt brackets, typically placed in the centre of the autoclave, providing approximately twice the usable width and depth of chamber space. | Modifies Chamber Loading Capabilities |
| AAN532 | Additional Shelf For AAN530 Shelf Rack | An additional shelf on anti-tilt brackets, typically placed in the centre of the autoclave, providing approximately twice the usable width and depth of chamber space. | Modifies Chamber Loading Capabilities |
| IQ/OQ001 | IQ/OQ Documents Package | Completion of the Installation Qualification (IQ) and Operational Qualification (OQ) documentation by an Astell Service Engineer. Requires verification to be valid. | Compliance / Regulatory Feature |
| IQ/OQ003 | Completion of IQ/OQ Documentation | Completion of the Installation Qualification (IQ) and Operational Qualification (OQ) documentation by an Astell Service Engineer. Requires verification to be valid. | Compliance / Regulatory Feature |
| UKAS001 | UKAS Calibration | Calibration of the autoclave to specified temperatures as per the requirements of ISO 17025:2005. | Compliance / Regulatory Feature |
| UKASVAL | Load Validation | Multipoint Load Validation Service provided by an Astell Services Autoclave Engineer. | Compliance / Regulatory Feature; Provides Validated Evidence of Load Meeting Requirements |
AMB240 - 63 Litre Ecofill Benchtop Autoclave
The AMB240 is a Low Water and Power Consumption 63 Litre Ecofill Benchtop Autoclave with a circular front-facing chamber aperture and the Astell Ecofill water and heat recycling system. It is compatible with optional components for additional sterilization, documentation, cooling, connectivity, validation and compliance requirements.
| Model code | AMB240 |
|---|---|
| Product name | 63 Litre Ecofill Benchtop Autoclave |
| Range | Low Water and Power Consumption |
| Product type | Benchtop Ecofill Autoclave with a Circular Front Facing Chamber Aperture |
| Description | An Astell autoclave with a 63 litre chamber that has a circular front-facing aperture, with the Astell Ecofill water and heat recycling system. Compatible with a range of optional components to extend the range of sterilizable load types. |
AMB240 specifications
Air
| Specification | Value | Unit |
|---|---|---|
| Peak Air Flow For Air Ballast | N/A | Litres per minute |
| Connecting Airline Hose Size For Air Ballast | N/A | mm |
| Peak Air Pressure For Air Ballast | N/A | bar |
| Second Airline Supply Connection Size | N/A | mm |
| Second Peak Air Supply Flow | N/A | Litres per minute |
| Second Peak Air Supply Pressure | N/A | bar |
| Second Air Supply Use | N/A |
Chamber
| Specification | Value | Unit |
|---|---|---|
| Chamber Depth | 671 | mm |
| Chamber Finish | Electropolished | |
| Chamber Height | 345 | mm |
| Chamber Volume | 63 | Litres |
| Chamber Width | 345 | mm |
Drain
| Specification | Value | Unit |
|---|---|---|
| Required Features of Drainage System | N/A | |
| Drain Material | N/A | |
| Drain Position | N/A | |
| Drain Size | N/A | mm |
| Drainpipe Connection | N/A | |
| Maximum Drain Height | N/A | mm |
Dimensions
| Specification | Value | Unit |
|---|---|---|
| Dry Weight | 134 | kg |
| Product Height | 605 | mm |
| Product Width | 520 | mm |
| Product Depth | 1006 | mm |
| Product Footprint | 0.32 | square metres |
Electrical
| Specification | Value | Unit |
|---|---|---|
| Max Frequency | TBC | Hz |
| Max Voltage | 230 | V |
| Max Wattage | TBC | kW |
| Standard Amperage | 13 | A |
| Power Of Steam Source | 2.3 | kW |
| Single Phase Availability | Available |
Water
| Specification | Value | Unit |
|---|---|---|
| Maximum Water Flow Rate | Infinity | Litres per minute |
| Minimum Water Flow Rate | 0 | Litres per minute |
| Water Enters Via | a water jug, filled from a tap |
Doors
| Specification | Value | Unit |
|---|---|---|
| Number Of Doors | 1 |
Process
| Specification | Value | Unit |
|---|---|---|
| Steam Source | In-chamber water heating element | |
| Fitted Vacuum System | Optional |
| Option code | Option name | Description | Features |
|---|---|---|---|
| No options listed in the source data. | |||