95 - 135 Litre Top Loading Autoclave

Model: AMA250 Heaters in chamber (95 litres)
Model: AMA260 Heaters in chamber (120 litres)
Model: AMA270 Heaters in chamber (135 litres)

95 - 135 Litre Top Loading Autoclave

The 95 - 135 litre toploading autoclave range offers increased chamber sizes compared to the 'Compact' units, as well as featuring advanced options not available on smaller sized autoclaves, including Heated Jackets, Integral Steam Generators, Simple/Advanced Vacuum and Cooling options.

These options enable a top loading sterilizer to be tailored to the needs of the customer by speeding up cooling, dealing with liquids, porous-type loads and allowing a wider range of items to be efficiently processed.

Astell autoclaves are used in scientific research worldwide.  View selected peer-reviewed research papers that reference their use in experimental methodology. 

Contact us now on +44 (0)20 8309 2031 to find out more, or request a quotation by clicking here. For organisations outside the UK, please contact your national dealer who can be found on our Find a Dealer page.

Range Classification


The option to purchase additional features means that this range is highly versatile and can be used for a large range of sterilizing situations. As standard, the autoclave is fitted with heaters in the base of the chamber and can be used for sterilizing liquids (media), discard, glassware and other instruments. Selecting the optional Integral Steam Generator will help to improve efficiency and cycle times.

Direct steam models are available at no extra cost.

Astell can custom build the Top Loading range to your specifications.

This product has received Sustainability Awards from SLS. Click to find out more.

Sustainable Use AwardSustainable Raw Material AwardSustainable Distribution and Packaging AwardSustainable Product Manufacturing AwardSustainable Disposal Award


View Products in Stock

Features

Product Options

  • 21 CFR 11 controller software 21 CFR 11 controller software
  • Advanced Pulsar Vacuum Advanced Pulsar Vacuum
  • Advanced Water Cooling Advanced Water Cooling
  • Air Ballast Air Ballast
  • Assisted Air Cooling (only available for non-vacuum models) Assisted Air Cooling (only available for non-vacuum models)
  • Autodrain - automatic chamber drain Autodrain - automatic chamber drain
  • Autofill - automatic chamber water filling Autofill - automatic chamber water filling
  • Blowdown Vessel Blowdown Vessel
  • CAT III (BSL3) compliance CAT III (BSL3) compliance
  • Morrison Discard Container (390x500mm or 390x355mm) Cylindrical Morrison Discard Container
  • Exhaust Heat Exchange System (drain cooling) Drain cooling
  • Ethernet interface Ethernet interface
  • Heated Jacket Heated Jacket
  • Integral Air Compressor Integral Air Compressor
  • Integral Data Printer Integral Data Printer
  • Integral Steam Generator Integral Steam Generator
  • IQ/OQ documentation IQ/OQ documentation
  • Lifting hoist Lifting hoist
  • Load Sensed Process Timing Load Sensed Process Timing
  • Load Support Plate Load Support Plate
  • Nelldorn Glassware Dryer Nelldorn Glassware Dryer
  • Pulsar Freesteaming (only available on non-vacuum models) Pulsar Freesteaming ( Not compatible with Simple Vacuum )
  • Remote maintenance/diagnosis Remote maintenance/diagnosis
  • Simple Vacuum Simple Vacuum
  • Stainless Steel basket (400x400mm or 400x220mm) Stainless Steel basket (400x400mm or 400x220mm)
  • Water Softener Water Softener

Related Case Study

Imperial: Case Study

"Once again Astell has come up with a really practical solution. 

The autoclaves really live up to ‘plug and play’ description and their whole service is excellent."

Dominic Smith. Laboratory Operations Manager. Imperial College London - Faculty of Medicine.

Read

JW Lees Brewery: Case Study

When brewers JW Lees finally had to replace a 30 year-old Astell autoclave… they chose a new Astell autoclave.

Read

Vets Now: Case Study

Compact autoclave with vacuum facilities rapidly cools the chamber leaving surgical instruments touch dry for Vets Now.

Read

SLS Sustainable Features Awards

This autoclave has been recognized by Scientific Laboratory Supplies for its outstanding sustainable features through the following awards.

Sustainable Use Award

Sustainable Raw Material Award

Material resource efficiency principles have been embedded into the design.

Sustainable Raw Material Award

Sustainable Product Manufacturing Award

Feature of manufacturing process designed to generate less waste.

Sustainable Distribution & Packaging Award

Sustainable Distribution & Packaging Award

Manufacturing facility located in UK or Ireland. Country of origin has an Environmental Performance Index (EPI) greater than 60 (2022). Plastic free packaging. Product reduces need for packaging. Packaging return scheme offered.

Sustainable Product Manufacturing Award

Sustainable Use Award

Product feature reduces energy consumption. Product feature reduces water consumption. Built to last. Minimum 5+ year warranty with software support (if applicable) and spare parts and servicing available.

Sustainable Disposal Award

Sustainable Disposal Award

Product is recyclable (supplier must offer a recycling or repurposing scheme for lab products) – excludes packaging.

Icons courtesy of Scientific Laboratory Supplies

Specifications and Options for Top Loading Autoclaves

AMA250 - 95 Litre Top Loading Autoclave

The AMA250 is a Customisable and Versatile 95 litre top loading autoclave with a circular upward-facing chamber aperture. It is designed to support optional components and steam generation methods for multiple sterilization load types.

AMA250 product summary
Model codeAMA250
Product name95 Litre Top Loading Autoclave
RangeCustomisable and Versatile
Product typeAutoclave with a Circular Upward Facing Chamber Aperture
DescriptionAn Astell autoclave with a 95 litre chamber that has a cylindrical upward-facing aperture. Designed to support a wide range of optional components and steam generation methods, enabling sterilization of multiple load types.

AMA250 specifications

Air

AMA250 air specifications
SpecificationValueUnit
Peak Air Flow For Air Ballast100Litres per minute
Connecting Airline Hose Size For Air BallastTBCmm
Peak Air Pressure For Air BallastTBCbar
Second Airline Supply Connection SizeTBCmm
Second Peak Air Supply FlowTBCLitres per minute
Second Peak Air Supply PressureTBCbar
Second Air Supply Usesimple or advanced vacuum

Chamber

AMA250 chamber specifications
SpecificationValueUnit
Chamber Depth456mm
Chamber FinishElectropolished
Chamber Height584mm
Chamber Volume95Litres
Chamber Width456mm

Drain

AMA250 drain specifications
SpecificationValueUnit
Required Features of Drainage SystemVenting
Drain MaterialCopper
Drain Positionabove floor
Drain Size35mm
Drainpipe ConnectionBetween Autoclave and Main Building Drain Only
Maximum Drain Height130mm

Dimensions

AMA250 dimensions specifications
SpecificationValueUnit
Dry Weight173kg
Product Depth843mm
Product Footprint0.55square metres
Product Height973mm
Product Width660mm

Electrical

AMA250 electrical specifications
SpecificationValueUnit
Max Frequency50Hz
Max VoltageTBCV
Max Wattage10kW
Standard AmperageTBCA
Power Of Steam SourceTBCkW
Three Phase AvailabilityAvailable

Water

AMA250 water specifications
SpecificationValueUnit
Maximum Water Flow RateInfinityLitres per minute
Minimum Water Flow Rate0Litres per minute
Water Enters Viaa water jug, filled from a tap

Doors

AMA270 doors specifications
SpecificationValueUnit
Number Of Doors1

Process

AMA270 process specifications
SpecificationValueUnit
Steam SourceIn-chamber water heating element
Fitted Vacuum SystemOptional
AMA270 available options
Option codeOption nameDescriptionFeatures
AAQ503EXTExternal Air CompressorAllows the autoclave to use more than one steam source.Requires Additional Power Socket
AAQ503Integral Air CompressorProvides compressed air for autoclave systems that require it.
AJP150CChamber Vessel Cooling JacketThe sterilization chamber vessel is encapsulated within another vessel, and the space between can be filled with water to cool the chamber walls. Provides rapid cooling.Provides Cooling; Requires Water Supply; Speeds Up Cycle Times
AAR122Ethernet InterfaceAllows the autoclave controller to be monitored from compatible digital systems.Data / Connectivity Feature
AAR130Integral Data-PrinterAllows for the generation of physical records.Generates Cycle Records and Printouts
AVC002SSimple VacuumProvides a vacuum phase before and after sterilization to aid with air removal and load drying, reducing time to sterilization. Suitable for use with in-chamber steam generation.Improves Air Removal; Requires Compressed Air; Speeds Up Cycle Times
AAP080Chamber Vessel Cooling Water CoilsPipework coiled around the sterilization chamber vessel allows water to be circulated around the outside, improving cooling times.Provides Cooling; Requires Water Supply; Speeds Up Cycle Times
AAR014Load Sensed Process TimingA temperature probe with an armoured lead is added to the chamber. Placed inside fluid loads, this probe provides accurate measurement of liquid temperatures, allowing for faster and more controlled liquid sterilization.Fluid Handling Safety Feature; Improves Liquid Loads
AJP150Chamber Vessel Heating JacketThe sterilization chamber vessel is encapsulated within another vessel, and the space between can be filled with steam to heat the chamber walls. Provides improved heating speeds, and load drying after sterilization.Improves Drying; Improves Porous Loads; Required For Porous Loads; Required For Wrapped Loads; Requires Steam; Speeds Up Cycle Times
AVC001SAdvanced VacuumProvides pre- and post-sterilization vacuum phases, using negative and positive pressure pulsing to remove air from the chamber and load before sterilization, and a drying stage after sterilization. When combined with a Chamber Vessel Heating Jacket, drying performance is enhanced.Improves Air Removal; Improves Drying; Improves Porous Loads; Provides Vacuum Cooling; Required For Porous Loads; Required For Wrapped Loads; Requires Compressed Air; Requires Water Supply; Speeds Up Cycle Times
AVC004Air BallastMaintains chamber pressure during the cooling of fluid loads, greatly reducing the likelihood of boil-over. Requires suitable compressed air, and works best when paired with Load-Sensed Process Timing and a Cooling Jacket.Fluid Handling Safety Feature; Improves Fluid Discard; Improves Liquid Loads; Requires Compressed Air; Speeds Up Cycle Times
CFR021FDA 21 CFR Part 11 Compliant Controller SoftwareProvides compliance to the requirements of 21 CFR Part 11 through data security, data integrity, traceability/audit trails, and electronic signature rules.Compliance / Regulatory Feature; Data / Connectivity Feature
HST040KGChamber Loading HoistSimplifies the load-handling process. A powered winch lifts items up to 40 kg from floor level, and a mechanical boom arm allows it to be positioned and lowered into the chamber.
DSSSteam SeparatorEnhances the quality of steam supplied to the autoclave, ensuring its suitability for sterilization.
AVQ006SCAT III (CL3 / BSL3) ComplianceEnhanced containment methods prevent unsterilized pathogens from leaving the autoclave, meeting the requirements of CAT III compliance for Containment Level 3 / Biosafety Level 3.Compliance / Regulatory Feature
RSSC70Secondary ControllerA secondary screen used on double-door pass-through autoclaves, allowing the operator to view the controller displayed information from the opposite door.Provides Additional Functionality for Passthrough Systems Only
AAN420Drain CoolingCools effluent (waste water) before it leaves the autoclave. For sites without thermal-shock-resistant drains. Requires a mains water supply.Provides Installation Site Remediation; Requires Water Supply
AAP006Chamber Vessel Cooling Fan SystemBlows air across the external surfaces of the sterilization chamber vessel to improve cooling times.Provides Cooling; Speeds Up Cycle Times
AAP018AutodrainAutomatically drains the in-chamber steam generation assembly at the end of a cycle, allowing the sterilization chamber to cool faster.Improves Cooling Times
AAP019AutofillAllows automatic refilling of the in-chamber steam generation assembly. Requires mains water supply.Automates Chamber Filling; Requires Water Supply
12KWSG12kW Integral Steam GeneratorReplaces the in-chamber steam generation assembly with hardware positioned outside the sterilization chamber to provide enhanced steam control and functionality. Requires mains water supply.Required For Porous Loads; Required For Wrapped Loads; Requires Water Supply; Speeds Up Cycle Times
AAB001Blow Down VesselFor use with an integral or stand-alone steam generator. The autoclave can be set to expel high-pressure steam to remove dissolved gases and debris from its components; this vessel safely captures the expelled condensate and debris during the blow-down process.Improves System Longevity; Pressure System Blow-Down Safety Feature
CWS300Water Softener and Installation KitExtracts limescale-causing minerals from the water supply before they enter the autoclave, reducing the likelihood of limescale fouling the autoclave.Provides Softened Water Supply; Requires Water Supply
AAQ525External Air CompressorProvides compressed air for autoclave systems that require it.Requires Additional Power Socket
AAN036Stainless Steel Wire BasketA cylindrical basket that simplifies the load handling process with minimal effect on the thermal attributes of the load.
AAN042Stainless Steel Wire BasketA cylindrical basket that simplifies the load handling process with minimal effect on the thermal attributes of the load.
AAN056Morrison Discard ContainerA cuboid container that allows the loading and unloading of multiple items simultaneously.Simplifies Loading and Unloading Procedures
AAN058Morrison Discard ContainerA cuboid container that allows the loading and unloading of multiple items simultaneously.Simplifies Loading and Unloading Procedures
IQ/OQ003Completion of IQ/OQ DocumentationCompletion of the Installation Qualification (IQ) and Operational Qualification (OQ) documentation by an Astell Service Engineer. Requires verification to be valid.Compliance / Regulatory Feature
UKAS001UKAS CalibrationCalibration of the autoclave to specified temperatures as per the requirements of ISO 17025:2005.Compliance / Regulatory Feature
IQ/OQ001IQ/OQ Documents PackageCompletion of the Installation Qualification (IQ) and Operational Qualification (OQ) documentation by an Astell Service Engineer. Requires verification to be valid.Compliance / Regulatory Feature
UKASVALLoad ValidationMultipoint Load Validation Service provided by an Astell Services Autoclave Engineer.Compliance / Regulatory Feature; Provides Validated Evidence of Load Meeting Requirements